{"product_id":"hanna-instruments-low-range-ph-conductivity-tds-combo-pen-hi98129-hanna","title":"Hanna Instruments Low Range pH\/Conductivity\/TDS Combo Pen HI98129 - Hanna","description":"\u003cdiv class=\"product-view\"\u003e\n\u003cdiv class=\"productView\" data-event-type=\"product\" data-entity-id=\"4856\" data-name=\"Low Range pH\/Conductivity\/TDS Tester\" data-product-category=\"Industry\/Industrial, \n            Industry\/Industrial\/Chemical manufacturing, \n            Industry\/Industrial\/Water treatment, \n            Industry\/Water, \n            Industry\/Water\/Aquaculture, \n            Industry\/Water\/Pool, spa, and cold plunge, \n            Industry\/Water\/Wastewater, \n            Industry\/Water\/Drinking water, \n            Industry\/Industrial\/Plating, \n            Industry\/Laboratory, \n            Industry\/Laboratory\/Research, \n            Industry\/Food, \n            Industry\/Food\/Meat, \n            Industry\/Food\/Dairy, \n            Industry\/Food\/Processed foods, \n            Industry\/Beverage, \n            Industry\/Beverage\/Wine, \n            Industry\/Laboratory\/Education, \n            Industry\/Water\/Environmental, \n            Industry\/Industrial\/Petrochemical, \n            Industry\/Beverage\/Beer, \n            Parameters\/P - Z\/pH, \n            Industry\/Water\/Aquarium, \n            Product\/Testers, \n            Industry\/Food\/Maple and honey, \n            Parameters\/G - O\/Multiparameter, \n            Industry\/Agriculture, \n            Parameters\/A - F\/EC\/TDS, \n            Parameters\/P - Z\/TDS, \n            Hanna best sellers, \n            Best Sellers, \n            Wastewater\/Wastewater testing equipment for Municipalities, \n            Wastewater\/Wastewater testing equipment, \n            Wastewater\/Wastewater testing equipment for Manufacturers, \n            Wastewater\/Wastewater portable testing equipment\" data-product-brand=\"Hanna Instruments\" data-product-price=\"224.99\" data-product-variant=\"single-product-option\"\u003e\n\u003csection class=\"productView-details product-options\"\u003e\n\u003cdiv class=\"productView-shortDescription\"\u003e\n\u003cp\u003eThe low range Combo® pH, EC, TDS (ppm) and temperature meter is one of Hanna's most popular meters. The waterproof design, simple operation, and replaceable electrode mean that you can rely on this meter for years.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe HI98129 is designed for low range use (0 to 3999 µS\/cm or 0-2000 ppm). Choose the HI98130 for the high range model.\u003c\/li\u003e\n\u003cli\u003eCompact \u0026amp; waterproof design fits right in your pocket so you can take it anywhere.\u003c\/li\u003e\n\u003cli\u003eReplaceable pH electrode extends the life of your tester for years.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003cdiv data-content-region=\"product-before-description\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv data-name=\"related-target\" data-position=\"2\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"productView-description\" data-event-type=\"product\"\u003e\n\u003csection data-content-region=\"product-description-split\"\u003e\u003c\/section\u003e\n\u003cbr\u003e\n\u003c\/div\u003e\n\u003csection class=\"banner--product-col2-details grid-container\"\u003e\n\u003cdiv class=\"col2-detail-group grid-x grid-padding-x grid-padding-y align-right\"\u003e\n\u003cdiv class=\"cell small-12  border-after--blue-wide\"\u003e\n\u003cdiv class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003cp\u003eThe HI98129 is an easy-to-use and accurate waterproof pH, conductivity, TDS (ppm) tester. It measures pH, EC in the low range (0 to 3999 µS\/cm), TDS (0 to 2000 ppm), and temperature. This floating, waterproof combination pocket tester has an easy to read, LCD and an automatic shut-off. All pH, EC, and TDS (ppm) readings are automatically temperature compensated (ATC) to prevent temperature-related variations in your measurements. For EC and TDS (ppm) readings, the EC\/TDS conversion factor (CONV) is selectable by the user, as well as the temperature compensation coefficient ? (BETA).\u003c\/p\u003e\n\u003ch4\u003eReplaceable pH Electrode Cartridge\u003c\/h4\u003e\n\u003cp\u003eThe HI98129 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!\u003c\/p\u003e\n\u003ch4\u003eHigh Accuracy EC and TDS (ppm) Tester Probe\u003c\/h4\u003e\n\u003cp\u003eThe graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits in the solution. The exposed temperature sensor provides fast response times and guarantees highly accurate temperature compensated readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col2-detail-group grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-6\"\u003e\n\u003ch2 class=\"section-header\"\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cell small-12\"\u003e\n\u003cdiv class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto small-order-1 large-order-2\"\u003e\n\u003ch4\u003eStability indicator\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHOLD button\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eFreezes reading on the display to allow recording of measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBEPS (Battery Error Prevention System)\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeter will automatically shut off if there is not enough power to get an accurate measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eBattery % level at startup\u003c\/h4\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWhen the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAuto-off\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAuto-off feature automatically shuts off meter after 8 minutes of non-use to maximize battery life\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-details=\"\" class=\"cell small-12 large-auto small-order-2 large-order-1\"\u003e\n\u003cdiv data-detail-item=\"\" class=\"grid-x grid-padding-x grid-padding-y\"\u003e\n\u003cdiv class=\"cell small-12 large-auto\"\u003e\n\u003ch4\u003e3 sensors in a single tester\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003epH electrode with extractable junction\u003c\/li\u003e\n\u003cli\u003eAmperometric EC\/TDS sensor\u003c\/li\u003e\n\u003cli\u003eExposed temperature probe for faster EC and TDS (ppm) readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWaterproof\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned to float if accidentally dropped in sample\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWide pH Range\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003epH range is from 0.00 to 14.00 pH\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSelectable EC to TDS (ppm) conversion factor\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eChoice of either a 0.45 or 1.0 conversion factor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAutomatic Temperature Compensation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAll readings are compensated for variations in temperature\u003c\/li\u003e\n\u003cli\u003eTemperature displayed in \u003csup\u003eo\u003c\/sup\u003eC or \u003csup\u003eo\u003c\/sup\u003eF along with pH, EC or TDS reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003c\/div\u003e\n\u003csection class=\"banner--product-resources\"\u003e\n\u003cdiv class=\"custom-fields\"\u003e\n\u003cdiv class=\"flex-center\"\u003e\n\u003cdiv class=\"resources-container\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"tabs-content\" data-tabs-content=\"HI98129-responsiveaccordiontabs\"\u003e\n\u003cspan class=\"\"\u003e\u003c\/span\u003e\n\u003cdiv id=\"specifications-accordion\" class=\"tabs-panel is-active\" role=\"tabpanel\" data-tab-content=\"\" aria-labelledby=\"specifications-accordion-label\" aria-hidden=\"true\"\u003e\n\u003cdiv class=\"grid-container\"\u003e\n\u003cdiv class=\"table-specs\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Ranges\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Accuracy (@25°C\/77°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Temperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic, one point at 1413 μS\/cm or 1382 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Correction Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eautomatic with у adjustable from 0.0 to 2.4% \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC to TDS Conversion Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI73127 (replaceable included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic Shut-Off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eauto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F) RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEach HI98129 is delivered in a cardboard box and is supplied with: HI70004 pH 4.01 buffer solution, 20 mL sachet (1 pc.), HI70007 pH 7.01 buffer solution, 20 mL sachet (1 pc.), HI70300N Storage solution for pH \u0026amp; ORP electrodes, 20 mL sachet (1 pc.), HI70031 1413 μS\/cm conductivity standard, 20 mL sachet (1 pc.), HI70032 1382 ppm TDS standard, 20 mL sachet (1 pc.), HI700601 pH \u0026amp; ORP electrode cleaning solution, 20 mL sachet (1 pc.), HI73127 pH electrode, HI73128 Electrode removal tool, 1.5V batteries (4 pcs.), Instrument quality certificate, \u0026amp; Instruction manual.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 year\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e","brand":"Hanna","offers":[{"title":"Default Title","offer_id":46406785630387,"sku":null,"price":239.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0245\/1727\/9828\/files\/211107-hannainstruments-ph-ec-tds-tester-ph-electrode-testing-fr.webp?v=1794082951","url":"https:\/\/www.cincinnaticoral.com\/products\/hanna-instruments-low-range-ph-conductivity-tds-combo-pen-hi98129-hanna","provider":"Cincinnati Coral and Aquarium","version":"1.0","type":"link"}